Spo2 99



  • Normal SpO2 values vary between 90 and 100%. Good blood oxygenation is necessary to supply the energy your muscles need in order to function, which increases during a sports activity. If your SpO2 value is below 90%, that could be a sign of poor blood oxygenation, also called hypoxia.
  • Using a pulse oximeter device, saturation of peripheral oxygen (SpO2) is an estimation of the oxygen saturation level. For a regular healthy person, the normal blood oxygen saturation level (SpO2) is around 94% to 99%. For patients with mild respiratory diseases, the SpO2 is around 90% or above.

Spo2 95%: N: Normal healthy individual: Spo2 91% - 95%: N: Clinically acceptable, but low. Patient may be a smoker, or be unhealthy. Spo2 70% - 90%: Y: Hypoxemia. Unhealthy and unsafe level.

Finger Pulse Oximeter Parameters - OctiveTech 300-series

1. Overview

This document contains an overview of suggested operating parameters for the OctiveTech series of Finger Pulse Oximeters. This document is intended to be a guide only, and should not be used as a substitute for clinical diagnosis performed by a licensed practitioner.

Spo2 99 Means

2. Extended Specifications

Spo2 MeasurementsPulse Rate
Range: 0% - 100%
Resolution: 1%
30-254 BPM
Resolution: ±1bpm
Accuracy: 80% - 99%, ±2%Accuracy: ±2bpm or ±2%
Accuracy: 70% - 79%, ±3%Accuracy: 0% - 69%, unspecified

3. Measurement Interpretation

This section contains a guideline on various levels of blood oxygen and heart rate that are within tolerable ranges.

3.1 Oxygen Saturation

Spo2 92% means
MeasurementCriticalNotes
Spo2 > 95%NNormal healthy individual
Spo2 91% - 95%NClinically acceptable, but low. Patient may be a smoker, or be unhealthy.
Spo2 70% - 90%YHypoxemia. Unhealthy and unsafe level.
Spo2 < 70%YExtreme lack of oxygen, ischemic diseases may occur. The OctiveTech 300-series of Oximeters is not calibrated to detect readings lower than 70%.

3.2 Resting Pulse Rate

Spo2Spo2
MeasurementCriticalNotes
PR <40 BPMYBelow healthy resting heart rates. OctiveTech 300-series does not detect pulse rates lower than 30BMP.
PR 40-60 BPMY/NResting heart rate for sleeping.
PR 60-100 BPMNHealthy adult resting heartrate.
PR 100 BPM – 220 BPMYAcceptable if measured during exercise. Not acceptable if resting heartrate.
PR > 220 BPMYAbnormally high heart rate. The OctiveTech 300-series does not detect heart rates > 254 BPM.

What are the different types of pulse oximeters?

There are 3 mains types of pulse oximeters—fingertip pulse oximeters, pediatric pulse oximeters, and handheld pulse oximeters.

Fingertip pulse oximeters

Spo2 99

Most commonly used in patient’s homes, fingertip pulse oximeters work by measuring the blood oxygen saturation levels using the finger. Although not as common, they can also be implemented using the earlobe. Fingertip pulse oximeters are generally transportable, making them extremely convenient when measuring blood oxygen saturation levels.

Pediatric pulse oximeters

Also known as a fetal pulse oximeter, pediatric pulse oximeters are designed to fit the smaller fingers of young children and infants. Often times it can be challenging to get a young child or baby to comply with normal pulse oximetry protocol. As a result, pediatric pulse oximeters have a probe that can attach to the head, allowing for an easier measurement of blood saturation levels.

Handheld pulse oximeters

Is 99 Spo2 Good

Primarily used by medical institutes and hospitals, handheld pulse oximeters are more complex and tend to give more accurate readings than fingertip pulse oximeters and pediatric pulse oximeters. Handheld pulse oximeters are used to measure the blood saturation levels of all age groups, ranging from neonates to adults, by attaching the probe to the finger—and in most cases, the index finger.


What Does Spo2 99 Mean

Disclaimer:

Spo2 99%

The information on this website aims to provide customers with relevant knowledge regarding our products. Under no circumstances should the information be used for therapeutic purposes. Customers must consult their doctors for the correct use of these information and products. ClinicalGuard.com is not responsible for any losses or accidents caused by the use of information on this website.